Fiber Optic Splice Closure Test Report
Product | Dome Type Fiber Optic Splice Closure | Brand | MAY |
Manufacturing Company | Shanghai May Telecom Co., Ltd | Test Category | Entrustment Inspection |
Sample Quantity | 10pcs | Serial Number | 20151003 |
Sampling Base | - | Testing Item | 17 |
Testing Standard | YD/T 814.1-2004 Fiber Closure Section 1: Outdoor Fiber Optic Splice Closure | ||
Testing Conclusion | 14 testing items of fiber optic splice closure are conducted in the testing center. All testing results are qualified with the standard and requirements in YD/T 814.1-2004 | ||
Comments | Temperature Range: -40℃ ~ +65℃ |
No. | Item | Conclusion |
1 | Appearance | Pass |
2 | Optical Performance | Pass |
3 | Sealing Performance | Pass |
4 | Re-sealing Performance | Pass |
5 | Tension | Pass |
6 | Crush | Pass |
7 | Impact | Pass |
8 | Bending | Pass |
9 | Torsion | Pass |
10 | Vibration | Pass |
11 | Temperature Cycle | Pass |
12 | High Temperature | Pass |
13 | Solar Radiation | Pass |
14 | Chemical Corrosion | Pass |
15 | Water Vapor Permeability | Pass |
First, Appearance and Structure:
No. | Item | Standard and Requirement | Test Result | Conclusion |
1 | Appearance | Complete shape, no burr, bubble, crack, empty warping, impurity, etc; The ground color should be even and continuous. | Complete, no defect, even and continuous ground color | Pass |
Second, Optical Performance:
No. | Item | Standard and Requirement | Test Result | Conclusion |
2 | Optical Performance | The excess fiber is coiled in the splice tray, the fiber connector has no excess loss (≤0.03dB) | 0.03, no excess loss | Pass |
Third, Sealing and Re-sealing Performance:
No. | Item | Standard and Requirement | Test Result | Conclusion |
3 | Sealing Performance | The closure with Air pressure 100kPa±5kPa is immersed into clean water at room temperature for 15min, there is no bubble, or for 24h, the barometer will not change. | No bubble, no air pressure change | Pass |
4 | Re-sealing Performance | Repeat the sealing three times. The closure with Air pressure 100kPa±5kPa is immersed into clean water at room temperature for 15min, there is no bubble, or for 24h, the barometer will not change. | No bubble, no air pressure change | Pass |
Fourth, Mechanical Performance:
No. | Item | Standard and Requirement | Test Result | Conclusion |
5 | Tension | Axial tensile force 1000N,
Air Pressure 100kPa±5kPa 1min, no air pressure change |
No air pressure change | Pass |
6 | Crush | Aerial, duct 1000N/100mm
Direct buried 2000N/100mm Air Pressure 60kPa±5kPa no air pressure change |
no air pressure change | Pass |
7 | Impact | Impact energy 16N·m
Time: 3 times Air Pressure 60kPa±5kPa air pressure change |
no air pressure change | Pass |
8 | Bending | Tension load 150N
Bending angle ±45o 10 cycles Air Pressure 60kPa±5kPa no air pressure change |
no air pressure change | Pass |
9 | Torsion | Torque 50N·m,
Torsion angle ±90o 10 cycles Air Pressure 60kPa±5kPa no air pressure change |
no air pressure change | Pass |
Fifth, Environmetanl Performance
No. | Item | Standard and Requirement | Test Result | Conclusion |
10 | Vibration | The closure with Air pressure 100kPa±5kPa can withstand the vibration with Frequency: 10Hz, amplitude: ±3mm at 106 times.
no air pressure change after the testing. The closure is immersed into clean water at room temperature for 15min, there is no bubble. |
No bubble, no air pressure change | Pass |
11 | Temperature Cycles | The closure is sealed and with air pressure 60kPa±5kPa, and then tested at 10 times cycles at lowest temperature of -40°C and highest temperature of +65°C. | No bubble, no air pressure change | Pass |
12 | High Temperature | Temperature: 65±2°C
Time: 100h Air pressure change <3kPa The closure is immersed into clean water at room temperature for 15min, there is no bubble. |
No bubble, no air pressure change | Pass |
13 | Solar Radiation | Radiation intensity: 1.12kW/m2
24 hours for a cycle: 8h irradiation, 16h non-irradiation, every radiation amount: 8.96 kW/m2 Temperature: 55 °C Duration: 3cycles (72 hours) After radiation, inflation pressure 60kPa±5kPa, impact energy 16N▪m, the number of impact: 3 times, pressure should have no change Immersing in container with normal temperature water, steadily observing for 15min, it should no bubble overflow All accessories should have no crack, damage and deformation |
Pressure: no change no bubble overflow no crack, damage and deformation | Pass |
Sixth, Mechanical Corrosion:
No. | Item | Standard and Requirement | Test Result | Conclusion |
14 | Mechanical Corrosion | The closure with Air pressure 60kPa±5kPa is immersed into solutions of 5%HCL, 5%NaOH and 5%NaCL for 24h. | No air pressure change, no corrosion on the surface of the closure | Pass |
15 | Water Vapor Permeability | The closure is immersed into the water of 60±2°C for 24h. | Water Vapor Permeability<0.05mg/h | Pass |