6.0 Test Results
6.1 Mechanical Shock (Impact Test)
After test, all samples have passed this procedure. No failure was observed. Test results are shown in the following tables and figures.
6.2 Variable Frequency Vibration Test
After test, all samples have passed this procedure. No failure was observed. Test results are shown in the following tables and figures.
6 3 Thermal Shock Test (not performed yet)
6.4 High Temperature Storage Test (Dry Heat)
Measurements were made at 168 hrs, 500hrs, l000hrs, 2000hrs, for the high temperature storage test. All samples have met the requirement and passed this procedure. Test results are shown in the following tables and figures.
6.5 High Temperature Storage Test (Damp Heat)
For high temperature storage (Damp Heat) test, after168hrs. 500hrs, l000hrs, 2000hrs, as required, all samples have passed the temperature storage test and meet the criteria. Test results are shown in the following tables and figures.
6.6 Low Temperature Storage Test
Measurements were made at 168 hours, 500hrs, 1000hrs. 2000hrs, for the low temperature storage test. All samples have passed this procedure. No failure was observed. Test results are shown in the following tables and figures.
6.7 Temperature Cycling Test
For temperature cycling test, after l00cls, 500cycles as required all samples have passed the temperature cycling test and met the criteria. Test results are shown in the following tables and figures.
6,8 Cyclic Moisture Resistance Test
After test. all samples have passed this procedure. No failure was observed. Test results are shown in the following tables and figures
6.9 Water Immersion Test
After test, all samples have passed this procedure. No failure was observed. Test results are shown in the following tables and figures