Fiber Cable Monitoring System: X-Fiber
Table 1: General Information
Equipment type | 16-1650D |
First release | 2.1 |
Width | 44 HP |
Height | 1HU |
Depth | 215mm (See Figure 55) |
Weight | < 2.0kg (4.4 lbs) |
Environmental conditions | Telcordia SR-3580 level 3 (NEBS), ETSI EN 300 019/1-3 Class 3.1 |
MTBF at 30°C ambient temperature | 216,124 h – 16/#1650D/AC 450,174 h – 16/#1650D/-48VDC |
Table 2: Mounting Kit
Part Number | Description | Usage |
1013904015 | /MK-SINGLE-19 | To mount one Unit in a rack unit (1RU), in a 19-inch rack. |
1013904016 | /MK-DUAL-19 | To mount two adjacent Units in 1RU, in a 19-inch rack. |
1013904017 | /MK-SINGLE-23 | To mount one Unit in 1RU, in a 23-inch rack. |
1013904018 | /MK-DUAL-23 | To mount two adjacent Units in 1RU, in a 23-inch rack. |
1013904040 | /MK-19-FLEX | To mount the Unit in a 19-inch or 21-inch rack for single or dual configuration. Use this mounting kit if you plan to perform an in-service upgrade from a single to dual configuration. |
1013904019 | /MK-SINGLE-19/1LGX | To mount the Unit and the 8/1CSM+1LGX#1650 in a 19-inch rack |
Table 3: Absolute Maximum Ratings
Storage temperature | -40 to 85 °C |
Ambient operating temperature | -5 to 55 °C |
Case temperature (during operation) | -5 to 70 °C |
Relative humidity (no condensation) | 85% |
TX peak optical power per port (maximum) | 100mW |
TX average optical power per port (maximum) | 1mW |
RX average optical power per port (max.before damage) | 10mW |
Table 4: OTDR Specification
Number of ports | 16 |
Distance range12 | up to 200km (160km for fingerprint) |
Distance accuracy3 | ± [0.8 + sampling resolution + 9.5 * 10-6 * distance] meter |
Sampling resolution | 0.1 … 1.6 meter (0.8 meter typically) |
Dynamic range4 | 39dB typically |
OTDR wavelength | 1639nm …1662nm, 1650nm typically |
Link loss measurement range with 15dBm laser power2 | Point-to-point with reflector: Minimum ≤ 40dB, Typical ≤ 42dB Point-to-point without reflector: Minimum ≤ 30dB, Typical ≤ 33dB |
OTDR: insertion loss scan time per port12 | 1 to 6 seconds (link loss ≤ 30dB), up to 15 seconds (link loss > 30dB) |
OTDR measurement time (per port) | 5 minutes maximum (depends on user input) |
Fiber loss measurement accuracy of the device (excluding inaccuracies of the WDM coupler and demarcation reflector, without DWDM signal)2 | ±1dB (at link loss < 30dB and link length < 90km) ±1.5dB (otherwise) |
Relative attenuation accuracy | ± 0.1dB3 |
Event dead zone (pulse width = 5ns; back reflection = -55dB; 25°C) | 0.8 meter (typically) |
Attenuation dead zone (pulse width = 5ns; back reflection = -55dB; 25°C) | 4 meters (typically) |
Supported pulse width | 5ns to 20000ns |
Sampling points | 256000 |
- The detection range, measurement time, or OTDR power budget might limit the scan
- The presence of a DWDM signal might reduce the measurement range and accuracy.
- Over temperature range, including aging, without fiber index uncertainties.
- 20µs pulse width, 5-minute averaging, max laser power, including post processing.
Table 5: Typical Dynamic Range Values at 25°C, including Post Processing
Pulse Width | Dynamic Range (SNR=1; using 15dBm laser power) | Measurement Conditions | ||
Fiber Length | Measurement Time | Sampling Resolution | ||
100ns | 22dB | 40km | 3 min | 0.8m |
1µs | 30dB | 80km | 3 min | 0.8m |
20µs | 38dB | 130km | 3 min | 1.6m |
- The presence of a DWDM signal also increases the measurement time (up to four times).
- For point-to-point with reflector.
- For point-to-point with reflector, no DWDM traffic, and overall loss < 30dB.
Table 6: Specifications for Monitoring Passive Optical Networks at 25°C
Maximum loss between Unit port and Reflector with 15dBm laser power1 | 37dB |
Maximum measurement length (dis-tance between Unit and Demarcation Reflector) | 80000m |
Minimum difference between the dis-tances of any two Demarcation Reflectors from the Unit | 3m |
Maximum number of Demarcation Reflectors | 128 |
Table 7: Link Loss Measurement Range for Passive Environment Surveillance Links at 25°C
High Dynamic | Standard2 | High Resolution | |
Link Loss Measurement Range with 15dBm Laser Power3 | 44dB | 39dB | 38dB |
Minimum Distance Between Sensors | 50m | 20m | 4m |
- With a higher loss, we cannot guarantee that the Unit detects a reflector. A meaningful maximum initial loss value for the operation is 35 dB, because only then can the system raise degradation alarms. The total budget includes the insertion loss of the split-ters and the WDM c
- In standard mode, measurements are much faster than in high resolution mode. Therefore the standard mode is a compromise for faster measurements over more accurate measurements.
- You will need 5 dB margin to accurately detect the sensor alarms.
Table 8: Sensor Detection Scan Time for Passive Environment Surveillance Links
High Dynamic | Standard | High Resolution | |
Link length | 60km | 40km | 20km |
Number of manhole sensors1 | 30 | 25 | 20 |
Intrusion detection scan time per port without water sensors2 | 10 seconds | 6 seconds | 30 seconds |
Intrusion detection scan time per port with water sensors2 | 25 seconds | 15 seconds | 100 seconds |
Table 9: Power Cables for Connecting the 16ALM/#1650D/-48VDC
Cable length of 3 meters (10 ft) | |
Sales Item Number | Cable Variant |
1036904052 | CBL/DC/300/3AWG16/PTB/RD-BK |
1036904053 | CBL/DC/300/3AWG16/PTB/GR-BL |
1036904054 | CBL/DC/300/3AWG16/PTB/BL-BK |
1036904092 | CBLZ/DC/300/2AWG14/PTB/BU-BK3 |
Cable length of 10 meters (32.8 ft) | |
Sales Item Number | Cable Variant |
1036904055 | CBL/DC/1000/3AWG16/PTB/R-/B+ |
Table 10: -48VDC Power Requirements for 16ALM/#1650D/-48VDC
Max input current | 0.2A |
DC input voltage | -72V to -36V (-48V typical) |
Transient current | 200mA |
Supply current rate of change | ±100mA/us |
Typical power consumption | 10W (25°C ambient temperature, 48V) |
Maximum power consumption | 13W |
Recommended external circuit breaker for full load conditions | Minimum 1A, maximum 6A hydraulic magnetic circuit breaker, characteristic curve C, D according to IEC/EN 60898 or similar. |
Power cord | Use of the cables provided by is mandatory. See Table 13. |
- The typical maximum number of manhole sensors = (specified measurement range- 18 – link loss without couplers)/0.31. See Table 11 for the measurement range.
- The intrusion detection scan time might vary depending on the actual link loss.
- The item number for the grounding/earthing terminal kit is 1036904093. This is a separate kit that you order.
Table 11: AC Power Requirements for 16ALM/#1650D/AC
Recommended external circuit breaker | 1A, type B or C, at 100V – 127V AC 1A, type B or C, at 220V – 240V AC1 |
Input voltage | 100V to 240V AC (+/- 10%) |
Frequency | 50Hz to 60Hz |
Rated input current | 250mA to 150mA |
Inrush current (1 ms after power on) | 4.8A |
Nominal power consumption | 10W at 240V; 9W at 100V |
Maximum power consumption under worst case conditions | 13W |
Table 12: AC Power Cords for 16ALM/#1650D/AC
Female coupler | AC Appliance Coupler according to IEC/EN 60320/C13 |
Power cord North America | plug type: NEMA 5-15P, NEMA 6-20 wall plug rating: 125V AC, 10A minimum power cord rating: 18/3 SVT, 125V AC, 10A, VW-1, 105 °C with L, N, and PE pin. |
Power cord Continental Europe2 | plug type: CEE 7/7 wall plug rating: 250V AC, 10A minimum power cord rating: 250V AC, 10A, H05VV-F, 105 °C, 3-pole |
Power cord United Kingdom | plug type: BS1363 wall plug rating: 250V AC, 10A minimum power cord rating: 250V AC, 10A, H05VV-F, 105 °C, 3-pole fuse type: 1A or 3A |
Power cord International | plug type: according to your local and national electrical codes with L, N, and PE pin. wall plug rating: 250V AC, 10A minimum power cord rating: 250V AC, 10A |
WDM Coupler Cable J-Y/SM/1CS+#1650/LC/0310
Table 1: General Information
Equipment Type | J-Y/SM/1CS+#1650/LC/0310 |
First release | 1.2.2 |
Length with cord | 3100mm (122 in) |
Length without cord | 65mm (2.6 in) without shrink tube 75mm (2.9 in) with shrink tube |
Weight | 0.015kg (0.033 lbs) |
Environmental conditions | Telcordia SR-3580 level 3 (NEBS), ETSI EN 300 019-1-3 Class 3.1 |
Temperature range | -33°C to +70°C (extended) |
Degree of protection according to IEC 60529 | IP20. Use in a pollution degree 2 environment and indoor controlled office environments only. |
MTBF at 25°C ambient temperature | 31,250,000h |
Table 2: Optical Interfaces
Number of Monitor (Mon) Ports | 1 x LC/APC |
Number of Client (C) Ports | 1 x LC/PC |
Number of Network (N) Ports | 1 x LC/PC |
Fiber Type | SM G.652 |
Table 3: Optical Characteristics
Maximum insertion loss1 | 1.2dB |
Average insertion loss | 0.6dB |
Average + 2Sigma2 | 0.9dB |
Directivity | 50dB |
Optical return loss | 40dB |
Passband for Monitor (Mon) Port | 1636nm to 1671nm |
Passband for Client (C) Port | 1262nm to 1618nm |
Isolation for Client (C) Port | 40dB |
Isolation for Monitor (Mon) Port | 15dB |
- When measuring the insertion loss of the coupler, any additional insertion loss of the connectors and test setup must be accounted and compensated for.
- Use this value for network planning.
Demarcation Reflector J/SM/DR/PTP/LC/0310
The J/SM/DR/PTP/LC/0310 is a single channel demarcation reflector patch cord. The J/SM/DR/PTP/LC/0310 comes with ruggedized fibers and can be used as any patch cord. The filter itself is a small metal tube located in the middle of the 310cm cable.
Table 1: General Information
Equipment Type | J/SM/DR/PTP/LC/0310 |
First release | 1.2.1 |
Form factor | patch cord |
Weight | 20g (.04 lbs) |
Length with cord | 3100mm (39.37 in) |
Length without cord | 65mm (2.5 in) |
Diameter | 3.2mm (0.1 in) |
Environmental conditions | Telcordia SR-3580 level 3 (NEBS), ETSIEN 300 019-1-3 Class 3.1 |
Temperature range | -40°C to +85°C (extended) |
MTBF at 25°C ambient temperature | 500,000,000h |
Table 2: Optical Interfaces
Network Port (N) (Data+ signal) | LC/PC – male |
Client Port (C) (Data signal only) | LC/PC – male |
Fiber Type | SM G.652 |
- When measuring the insertion loss of the reflector, any additional insertion loss of the connectors and test setup must be accounted and compensated for. The specified loss in this documentation includes one connector.
- Use these values for network planning.
Table 3: Optical Characteristics
Insertion loss Data Signal maximum value1 | 1.1dB for C-temp, 1.4dB for I-temp |
Insertion loss Data Signal average value | 0.5dB for C-temp, 0.7dB for I-temp |
Average + 2Sigma2 | 0.8dB for C-temp, 1.0dB for I-temp |
Optical Reflect Loss ( Signal) | 1.2dB for C-temp, 1.5dB for I-temp |
Passband for Reflect (network port) | 1636nm to 1671nm |
Passband for Client (data port) | 1262nm to 1618nm |
Isolation for Reflect (data and network port) | 20dB |
Isolation for Client (data and network port) | 40dB |