Figure 8 Self-supporting Aerial Fiber Optic Cable – GYTC8A

Cable Structure:
The 250um bare fibers are positioned in a loose tube made of a high modulus plastic. The tubes are filled with a water-resistant filling compound. A steel wire locates in the center of core as a metallic strength member. Tubes and fillers are stranded around the strength member into a compact and circular cable core. After an Aluminum Polyethylene Laminate (APL) moisture barrier is applied around the cable core, this part of cable accompanied with the stranded wires as the supporting part is completed with a polyethylene (PE) sheath to be figure 8 structure. This type of cable is specifically applied for self-supporting aerial installation.
Fiber Count | Tubes | Fillers | Cable Diameter (mm) | Tensile Strength (N) | Crush Resistance (N/100mm) | Bending Radius (mm) | Cable Weight (kg/km) | |||
Short Term | Long Term | Short Term | Long Term | Dynamic | Static | |||||
2~6 | 1 | 4 | 6.8×9.2×18.0 | 1,000 | 400 | 1,000 | 300 | 20D | 10D | 214 |
8~12 | 2 | 3 | 6.8×9.2×18.0 | 1,000 | 400 | 1,000 | 300 | 20D | 10D | 214 |
14~18 | 3 | 2 | 6.8×9.2×18.0 | 1,000 | 400 | 1,000 | 300 | 20D | 10D | 214 |
20~24 | 4 | 1 | 6.8×9.2×18.0 | 1,000 | 400 | 1,000 | 300 | 20D | 10D | 214 |
26~30 | 5 | 0 | 6.8×9.2×18.0 | 1,000 | 400 | 1,000 | 300 | 20D | 10D | 214 |
Remark:
The nominal value of the PE sheath thickness is1.6mm.
Temperature Range | -40°C~+70°C |
Fiber Type | SM 9/125um (1310nm/1550nm) | 62.5um (OM1) (850nm/1300nm) | 50um (OM2) (850nm/1300nm) | 50um (OM3) (850nm/1300nm) |
Maximum Attenuation (dB/km) | 0.8/0.6 | 3.5/1.5 | 3.5/1.5 | 3.5/1.5 |
Typical Attenuation (dB/km) | 0.4/0.3 | 3.5/1.5 | 3.0/1.0 | 3.0/1.0 |
Minimum LED Bandwidth (MHz·km) | — | 200/500 | 500/500 | 1500/500 |
Features:
- Good mechanical and temperature performance
- PE sheath protects cable from ultraviolet radiation
- High strength loose tube that is hydrolysis resistant
- Special tube filling compound ensure a critical protection of fiber
- High tensile strength of stranded wires meet the requirement of self-supporting and reduce the installation cost
- The following measures are taken to ensure the cable watertight:
- APL moisture barrier
- 100% cable core filling
- Loose tube filling compound
- Steel wire used as the central strength member
Standard:
- YD/T901-2001
- IEC 60794-1
Application:
- Self-supporting Aerial
Brand | MAY |
Name | GYTC8A: Figure 8 Self-supporting Aerial Fiber Optic Cable GYTC8A |
Fiber Count | 2=2 fibers 4=4 fibers 6=6 fibers 8=8 fibers 10=10 fibers 12=12 fibers … 28=28 fibers 30=30 fibers |
Fiber Mode | SM: SM 9/125um MM: 50/125um or 62.5/125um |
Fiber Type | 2D: SM G.652.D 7A1: SM G.657.A1 7A2: SM G.657.A2 7B2: SM G.657.B2 7B3: SM G.657.B3 OM1: MM 62.5/125um OM2: MM 50/125um OM3: MM 10G 50/125um OM4: MM 10G 50/125um |
Fiber Length | 0.5: 0.5km 1: 1km 1.5: 1.5km 2: 2km; etc |