1650nm Bidirectional Reflector - 1st Generation Optical parameter: Parameter Unit Min. Typ. Max. 1 Pass band wavelength range nm 1260-1625 2 Reflect band wavelength range nm 1645-1655 3.1 IL (1260nm-1360nm) dB 1.0 3.2 IL (1460nm-1600nm) dB 1.0 3.3 IL (1600nm-1625nm) dB 3.4 3.4 IL (REFLECT BAND) dB 25 4.1 RL (1260nm-1360nm) dB 35 4.2 RL (1460nm-1580nm) dB 35 4.3 RL (1580nm-1625nm) dB 25 4.4 RL (REFLECT BAND) dB 0 1.0 5 PDL (1260nm~1600nm) dB 0.4 6 Ripple (REFLECT BAND) dB 0.6 7 TDL (1260nm~1600nm) dB 0.5 8 Fiber – G657A2 Test Conditions: Use Yokogawa spectrometer (AQ6370D, Resolution: 0.2nm, Sensitivity: High1) to test by fiber fusion. The above test indexes include fusion loss. Dimension: Working/storage Conditions: Parameter Specification Unit Working temperature -25 ~ +65 °C Working humidity 5~95 %RH Storage temperature -25 ~ +65 °C Storage humidity 5~95 %RH