GJYFJU Outdoor Simplex Drop Cable


Description:
Outdoor single-core optical cables use a ф900um loose tube buffered optical fiber as the optical communication medium. The loose tube buffered optical fiber is wrapped with a layer of aramid yarn as a strength member, and is made of TPU jacket.
Features:
- Tight buffer fiber easy of stripping
- Tight buffer fiber have excellent flame-retardant performance
- Aramd yarn as strength member make cable have excellent tensile strength
- Corrosion resistance, waterproof, ultraviolet, flame retardant, environmental protection
Applications:
- Indoor integrated wiring
- Outdoor cabling
- Main wiring of the building
- Multicore optical fiber jumper
- Backbone Network
- Feeder and Distribution
- Access Network
Product standards:
YD/T1258.4, ICEA-596, GR-409, IEC60794-2-20/21, IEC60332-1 or IEC60332-3C
Fiber characteristics:
Fiber Type | G657A2 |
Color | red |
@1310nm | ≤0.36 dB/km |
@1550nm | ≤0.22 dB/km |
Structural parameters:
Sheath marking:
Manufacturer, Cable type, Manufacturing year, ID, Length marking in feet or meter.
Cable Type | Tubes | buffered fiber diameter mm | Buffered Fiber color | Cable diameter (mm) | Cable color | Thickness (mm) | Cable Weight(kg/km) |
TPU | |||||||
SXC-3.0 | 1 | 0.9±0.05 | Red | 3.0±0.1 | Black (RAL 9005) | 0.8 ± 0.1 | 8.6 |
Manufacturer, Cable type, Manufacturing year, ID, Length marking in feet or meter.
Mechanical resistance requirements:
REQUIREMENT | COMPLIANCE | STANDARD |
Tensile strength | 400 N | IEC 60794-1-2 – Method E1 |
Impact | 3Nm: reversible | IEC 60794-1-2 – Method E4 |
Cut-through resistance | 60 N | IEC 60794-1-2 – Method E12 |
Static bending | R = 15mm | IEC 60794-1-2 – Method E11 |
Kink | R =10 mm | IEC 60794-1-2 – Method E10 |
Torsion | 20 cycles ; L = 1m ; load = 20 N ; ± 180° ; Dα £ 0.1 dB | IEC 60794-1-2 – Method E7 |
Crush | Final level = 10daN/cm (Dα £ 0.1 dB) – reversibility checked at 20daN/cm | IEC 60794-1-2 – Method E3 |
Abrasion resistance of cable marking | N = 500 cycles ; F = 4 N | IEC 60794-1-2 – Method E2A |
Abrasion resistance of cable sheath | 100 N during 5 minutes | In house specification |
Environmental resistance requirements:
REQUIREMENT | COMPLIANCE | STANDARD |
Temperature cycling | Dα £ 0.1 dB/km between -5 °C and +60 °C (1550 nm) Dα £ reversible between -40 °C and +70 °C (1550 nm) | IEC 60794-1-2 – Method F1 |
Thermal ageing | (14 days at 70 °C) α £ 0.2 dB/km and reversible | In house specification |
Fire resistance | CPR certified: Eca class | IEC 60332-2-2 |
Resistance to UV radiation | Compliant | IEC 50289-4-17 – Method C |
Chemical behaviour | Oil, Acids, bases and solvents resistant | IEC 60811-404 – IEC 60811-501 |