GJYFJU Outdoor Simplex Drop Cable

GJYFJU Outdoor Simplex Drop Cable
GJYFJU Outdoor Simplex Drop Cable - Structure

Description:
Outdoor single-core optical cables use a ф900um loose tube buffered optical fiber as the optical communication medium. The loose tube buffered optical fiber is wrapped with a layer of aramid yarn as a strength member, and is made of TPU jacket.

Features:

  • Tight buffer fiber easy of stripping
  • Tight buffer fiber have excellent flame-retardant performance
  • Aramd yarn as strength member make cable have excellent tensile strength
  • Corrosion resistance, waterproof, ultraviolet, flame retardant, environmental protection

Applications:

  • Indoor integrated wiring
  • Outdoor cabling
  • Main wiring of the building
  • Multicore optical fiber jumper 
  • Backbone Network
  • Feeder and Distribution
  • Access Network

Product standards:
YD/T1258.4, ICEA-596, GR-409, IEC60794-2-20/21, IEC60332-1 or IEC60332-3C 

Fiber characteristics:
Fiber Type G657A2
Color red
@1310nm ≤0.36 dB/km
@1550nm ≤0.22 dB/km
Structural parameters:
Cable Type Tubes buffered fiber diameter mm Buffered Fiber color Cable diameter (mm) Cable color Thickness (mm) Cable Weight(kg/km)
TPU
SXC-3.0 1 0.9±0.05 Red 3.0±0.1 Black (RAL 9005) 0.8 ± 0.1 8.6
Sheath marking:
Manufacturer, Cable type, Manufacturing year, ID, Length marking in feet or meter.
Mechanical resistance requirements:
REQUIREMENT COMPLIANCE STANDARD
Tensile strength 400 N IEC 60794-1-2 – Method E1
Impact 3Nm: reversible IEC 60794-1-2 – Method E4
Cut-through resistance 60 N IEC 60794-1-2 – Method E12
Static bending R = 15mm IEC 60794-1-2 – Method E11
Kink R =10 mm IEC 60794-1-2 – Method E10
Torsion 20 cycles ; L = 1m ; load = 20 N ; ± 180° ; Dα £ 0.1 dB IEC 60794-1-2 – Method E7
Crush Final level = 10daN/cm (Dα £ 0.1 dB) – reversibility checked at 20daN/cm IEC 60794-1-2 – Method E3
Abrasion resistance of cable marking N = 500 cycles ; F = 4 N IEC 60794-1-2 – Method E2A
Abrasion resistance of cable sheath 100 N during 5 minutes In house specification
Environmental resistance requirements:
REQUIREMENT COMPLIANCE STANDARD
Temperature cycling Dα £ 0.1 dB/km between -5 °C and +60 °C (1550 nm) Dα £ reversible between -40 °C and +70 °C (1550 nm) IEC 60794-1-2 – Method F1
Thermal ageing (14 days at 70 °C)  α £ 0.2 dB/km and reversible In house specification
Fire resistance CPR certified: Eca class IEC 60332-2-2
Resistance to UV radiation Compliant IEC 50289-4-17 – Method C
Chemical behaviour Oil, Acids, bases and solvents resistant IEC 60811-404 – IEC 60811-501