MM OM4 1×2 Module FBT Coupler

MM OM4 1×2 Module FBT Coupler

MM OM4 1×2 Module FBT Coupler is designed for monitoring, diagnostic or maintenance purposes in data centre, enterprise, and telecommunication carrier networks.

For optimising performance, visibility and security of networks, MM OM4 1×2 Module FBT Coupler enables passive real-time network traffic monitoring with no disruption to performance.

1×2 Module FBT Coupler is multimode OM4 (50/125) and use an FBT optical splitter.

Split ratio options range from 50:50 to 90:10. All MM OM4 1×2 Module FBT Coupler is fully customizable to specific project requirements.

Features:

  • Low PDL
  • High Stability
  • High Directivity
  • Environmentally stable
  • Small package dimension
  • Low Polarization dependence
  • Low Insertion Loss and High Return Loss

Applications:

  • CATV
  • LAN & WAN
  • Telecommunication networks

Standards:

  • Telcordia GR-1209and GR-1221
Reliability Tests:
Tension 0.23kg, 1 minute
Impact 1.8m height, 3 axes, 8 times per axis
Vibration 10Hz~ 55Hz, amplitude 1.52mm, 3 axes, 4 hours per axis
Low Temperature -40±5°C, 5,000 hours
High Temperature 85±2°C, 5,000 hours
Water Immersion 43±2°C /PH5.5±0.5, 168 hours
Warm and Humidity 75±2°C/90±5%RH, 5,000 hours
Temperature Cycling -40±2°C~85±2°C, 300 periods, 2,400 hours
Specifications:
Port Configuration 1×2
Operating Wavelength 850nm
Coupling Ratio 1~50
Insertion Loss ≤4.4dB (Coupling ratio: 50/50)
Fiber Type Multi-mode 50/125um OM4
Fiber Diameter 900um
Package Dimension 90×20×10mm
Fiber Length 1 meter or customized
Operating Humidity ≤93%RH
Storage Humidity ≤93%RH
Operating Temperature -40~+85°C
Storage Temperature -40~+85°C
Note: About “@850nm, insertion loss: ≤4.4dB”, we use VCSEL Laser Source to test the insertion loss at 850nm. If other laser source is used to test the insertion loss, there might be big difference on insertion loss. So please advise us your laser source type if it is not VCSEL Laser Source.

Fiber Configuration:

Fiber Configuration - FBT Coupler

Application:

  • Tap cable inserted between points A and B
  • Tx is monitored from B
  • All data from B is received at A and C
  • Monitoring connector is an LC connectoror other type
  • Range of split ratios available
Ordering Information:
Brand MAY
Name FBT: FBT Coupler
Port 12: 1×2
Package M: Module
Fiber Mode OM4: MM 50/125um OM4 Fiber
Wavelength 8: 850nm
Cable Diameter 9: 900um
Cable Length 0.5: 0.5m
1: 1m
1.5: 1.5m
2: 2m; etc
Connector SU: SC/UPC
SA: SC/APC
FU: FC/UPC
FA: FC/APC
LU: LC/UPC
LA: LC/APC; etc
None: without connectors
Coupling Ratio 1: 1/99
3: 3/97
50: 50/50, etc