Distribution Cable Test Report
Test Date: March 18, 2017
Cable Type: GJPFJV-12B6
| Cable Type | GJPFJV-12B6 | ||
| Environmental Characteristics | -20~+70°C | Test Date | March 18, 2017 |
| Conclusion | The technical specification of product which provided was qualified with the request. | ||
| Remarks | Reference standard: IEC 60794-2-20 | ||
| Test Conclusion | Pass | Report Date | March 18, 2017 |
1. Dimension and jacket properties
| No. | Item | Requirement | Test Result | Conclusion |
| 1 | Buffer material | PVC | OK | Pass |
| 2 | Buffer diameter | 0.9±0.05mm | 0.89 | Pass |
| 3 | Jacket material | LSZH | LSZH | Pass |
| 4 | Jacket color | Yellow | OK | Pass |
| 5 | Jacket dimension | 6.8±0.2mm | 6.85 | Pass |
| 6 | Thickness of sheath | 1.0±0.1mm | 1.02 | Pass |
| 7 | Jacket finish | To be continuous, free from pinholes, splits, blisters, or other imperfections | OK | Pass |
| 8 | Cable marking | The cable shall be marked as agreed between the user and the manufacturer. | OK | Pass |
| 9 | Flame resistance (IEC 60332-1) | The distance between lower edge of upper clamping and the starting point of carbonation ≥50mm | 385 | Pass |
| The distance between lowest flame propagation point and lower edge of upper clamping ≤540mm | 480 | Pass | ||
| Date | March 18, 2017 | |||
2. Mechanical characteristics
| No. | Item | Requirement | Test Result | Conclusion |
| 1 | Tensile | 440N for 5min. No change in attenuation | 0.003 | Pass |
| No visible crack on the outer sheath | No crack | Pass | ||
| 2 | Crush | Force: 1000N (min). Duration: 1min. Length between test locations: 500mm. No change in attenuation |
0.0015 | Pass |
| No visible crack on the outer sheath | No crack | Pass | ||
| 3 | Impact | Radius of striking surface: 12.5mm. Impact energy: 1.0 joule Number of impacts: at least 3, each separated at least 500mm. |
No fiber breakage | Pass |
| 4 | Repeated bending | Bending radius: 20 times cable diameter Number of cycles: 100. Mass of weights: 4kg |
No fiber breakage | Pass |
| 5 | Torsion | Number of cycles: 10. Distance between fixed and rotation clamp: 1m. Tension load: 20N. |
No fiber breakage | Pass |
| 6 | Flexing | Number of cycles: 100. Pulley diameter: 20 times cable diameter. Mass of weights: 4kg (min.) |
No fiber breakage | Pass |
| 7 | Bend | Mandrel diameter: 20 times cable diameter. Number of turns per helix: 6. Number of cycles: 10. |
No fiber breakage | Pass |
| 8 | Kink | Minimum loop diameter: 20 times cable diameter. | No kink occur | Pass |
| Date | March 18, 2017 | |||
3. Environmental characteristics
| No. | Item | Requirement | Test Result | Conclusion | ||||
| 1 | Temperature cycling | -20~+70°C constant temperature at any point 8h, repeat two times, comparatively 20°C attenuation ≤0.4dB/km @1550nm | Fiber | -20°C | +70°C | Pass | ||
| 1310 | 1550 | 1310 | 1550 | |||||
| 1 | 0.037 | 0.005 | 0.039 | 0.004 | ||||
| 2 | 0.043 | 0.009 | 0.046 | 0.008 | ||||
| 3 | 0.042 | 0.015 | 0.044 | 0.01 | ||||
| 4 | 0.037 | 0.018 | 0.045 | 0.013 | ||||
| 5 | 0.021 | 0.024 | 0.015 | 0.035 | ||||
| 6 | 0.024 | 0.051 | 0.024 | 0.036 | ||||
| 7 | 0.051 | 0.018 | 0.028 | 0.034 | ||||
| 8 | 0.027 | 0.031 | 0.037 | 0.028 | ||||
| 9 | 0.031 | 0.024 | 0.034 | 0.019 | ||||
| 10 | 0.025 | 0.018 | 0.047 | 0.025 | ||||
| 11 | 0.034 | 0.061 | 0.041 | 0.025 | ||||
| 12 | 0.036 | 0.074 | 0.034 | 0.029 | ||||
| Fiber | Second circle | |||||||
| 1 | 0.016 | -0.0145 | 0.027 | 0.015 | ||||
| 2 | 0.056 | 0.018 | 0.03 | 0.018 | ||||
| 3 | 0.062 | 0.028 | 0.043 | 0.011 | ||||
| 4 | 0.071 | 0.028 | 0.052 | 0.042 | ||||
| 5 | 0.028 | 0.034 | 0.015 | 0.051 | ||||
| 6 | 0.029 | 0.035 | 0.024 | 0.027 | ||||
| 7 | 0.038 | 0.036 | 0.028 | 0.038 | ||||
| 8 | 0.031 | 0.034 | 0.037 | 0.034 | ||||
| 9 | 0.027 | 0.045 | 0.034 | 0.025 | ||||
| 10 | 0.016 | 0.034 | 0.057 | 0.051 | ||||
| 11 | 0.017 | 0.044 | 0.057 | 0.038 | ||||
| 12 | 0.037 | 0.034 | 0.025 | 0.049 | ||||
| Date | March 18, 2017 | |||||||