PON Power Meter is a testing meter for FTTx’s service and maintenance. It can measure voice, data and RF video signals over optical fiber links. The threshold data function that can be manually set via the instrument machine are more suitable for PON network engineering, construction and maintenance needs.
Features:
- Supports synchronous measurement and display of voice, data and video signals in a PON architecture
- Support simultaneous measurement of 1310nm upstream burst signal and 1490/1550nm downstream signal
- Support the software to connect MAY52 PON Power Meter with PC, to set threshold, to transfer data transfer and to calibrate wavelengths
- Support 1,000 data storage, which can be saved in PON Power Meter or PC for data review
- Supports optional VFL and OPM functions
- Offers up to 10 different threshold settings in total. Three status LEDs represent different optical signal conditions of Pass, Warn and Fail respectively.
- 10 minutes Auto-off function can be activated or deactivated
- Good key design,high sensitivity, greatly reducing the volume and weight of the tester.
- Different models corresponding to different function, according to own use to choose.
PON Power Meter Specification:
1310nm Upstream Measurement: | |
Pass Zone | 1260nm~1360nm |
Measurement Range | -40dBm~+10dBm |
Output Power (max) | 15dBm |
Isolation @ 1490/1550 | >40dB |
Burst Mode Measurement Error | <±0.5dB |
1490nm Downstream Measurement: | |
Pass Zone | 1470nm~1505nm |
Measurement Range | -40dBm~+12dBm |
Output Power (max) | 15dBm |
Isolation@1310/1550 | >40dB |
1550 Downstream Measurement: | |
Pass Zone | 1535nm~1570nm |
Measurement Range | -40dBm~+25dBm |
Output Power (max) | 25dBm |
Isolation @ (1310/1490nm) | >40dB |
Measurement Accuracy: | |
Connatural Uncertainty | ±0.5dB |
Linearity | ±0.1dB |
Passing Through Insertion Loss | <1.5dB |
General Information: | |
Detector Type | InGaAs |
Optical Connector | FC/SC Interchangeable/2.5 universal adapter |
Fiber Type | SM 9/125um |
Measurement Unit | dB/dBm/xW |
Resolution | 0.01dB |
Operation Voltage | DC 3.3V~5.5V |
Power Supply | 3pc*1.5V battery |
Continuously Operation Time | PON: 90h; OPM:100h; VFL: 50h |
Operation Temperature | -10℃~60℃ |
Storage Temperature | -25℃~70℃ |
Net Weight | 424g |
Note: The operation time of the battery are all for the instrument that do not turn on backlight, if the backlight turn on the operation time will be shorted.
PM Module (Power Meter, as optional function):
Measurement Accuracy: | |
Connatural uncertainty | ±0.5dB |
Linearity | ±0.1dB |
Measurement Range | -70dBm~+6dBm |
General Information: | |
Measurement Unit | dB/dBm |
Resolution | 0.01dB |
Calibration Wavelength | 1310/1490/1550/1625nm |
Detector Type | InGaAs |
Optical Connector | FC/SC Interchangeable/2.5 universal adapter |
VFL Module (Visual Fault Locator, as optional function):
Output power | >0.5mW |
Wavelength | 650nm |
Optical Connector | FC/SC Interchangeable/2.5 universal adapter |
Fiber Type | SM/MM |
Standard Accessories:
Item | Name | Quantity |
1 | MAY52 PON Power Meter with FC adapters | 1pc |
2 | SC adapters | 2pcs |
3 | USB cable | 1pc |
4 | Soft Bag | 1pc |
5 | CD with software inside | 1pc |
6 | User Manual | 1pc |
7 | AA alkaline battery | 3pcs |
Ordering Information:
Model: MAY52X-X-X
Model | X: Polish Type | X: OPM and VFL (optional) |
MAY52 | U: UPC | None: without OPM or VFL |
A: APC | AV: with VFL | |
AP: with OPM | ||
A: with OPM and VFL |